Operating instructions – Regency Hampton GC60 Large Pellet Stove OWNER'S MANUAL User Manual

Page 8

Advertising
background image

Operating Instructions

c

ontRoL

b

oaRd

F

unctionS

:

Note: The Control Panel is located underneath the units Cast Hopper Lid which is attached to a safety

switch that will immediatley stop the auger. The switch will stop operation of the stove and display a

#4 flash code if the lid is not closed within two minutes.

1. ON/OFF BUTTON: Used to turn the unit ON and OFF manually.
2. HEAT OUTPUT INDICATOR: Shows the present Heat Level output setting and the Feed Trim while

it is being adjusted.

3. THERMOSTAT SWITCH: Sets the unit’s control mode; AUTO/OFF or HIGH/LOW (when using a

Thermostat or Timer) or MANUAL.

4. FUEL TYPE LIGHTS: Shows the present Fuel Type selected; Premium Wood Pellets are Red, Regular

Wood Pellets are Green, and Low Grade Wood Pellets / Multi-Fuel

Pellets is Yellow. The Light flashes during start-up, and when the

Thermostat is in control of the Unit. The Light stops flashing when

the Exhaust Sensor closes.

5. FUEL TYPE BUTTON: Used to switch between three fuel type

modes: Premium Pellets for high grade wood pellets, Regular pellet

for mid grade wood pellets, and Low Grade for low grade wood

pellets and other pellet fuel types (corn, wheat, barley).

6. COMBUSTION AIR TRIM BUTTON: Increases or Decreases the

Fan voltage by 2.5volts on all feed settings. When pressed all lights

on Heat Level Indicator will come on except the one that is the

set point. Hold Trim Button down and press the UP or DOWN Heat

Level Arrow to adjust setting. #3 Light is the default setting.

Depending on Fuel quality Ignition problems may occur at higher

altitudes, this can be resolved by trimming the Combustion Fan to

a higher setting.

7. FEED TRIM BUTTON: Used in conjunction with the Heat Level

Adjustment Buttons to adjust the Feed Trim. It can be increased

by two (2) feed settings or it can be decreased by two (2) feed

settings. #3 Light is the default setting.

8. HEAT LEVEL ADJUSTMENT BUTTONS: Changes the Heat

Setting of the Unit from LO to HIGH. Press the Arrow Up button to

increase Heat, and Arrow Down to decrease Heat.

a

utomatic

S

aFety

F

eatuReS

oF

y

ouR

p

eLLet

S

tove

:

figure 2: circuit Board control

panel decal

A. EXHAUST TEMPERATURE SWITCH: The stove will shut off when the fire goes out and the exhaust

temperature drops below 49°C (120°F). It will display a #3 flash code.

B. HIGH LIMIT SAFETY SWITCH: If the temperature on the hopper reaches 93°C (200°F), the auger will

automatically stop, the stove will shut down, and it will display a #4 flash code. If this happens, call

your local dealer to reset the 93°C (200°F) high limit switch AND DETERMINE THE CAUSE OF THE

OVERHEATING.

C. VACUUM SWITCH: Notifies when the unit has lost vacuum. This can be caused by either a combustion

fan/vent failure, or simply the unit’s outer door, pedestal door. It will display a #2 flash code.

Sticker Front

Sticker Back

AUTO/OFF

HIGH/

LOW

MANUAL

Premium Grade Pellets
Regular Grade Pellets
Low Grade Pellets

1

2

3

4

5

HEAT

LEVEL

COMBUSTION

ON/OFF

FEED TRIM

FAN TRIM

FUEL TYPE

4

6

7

8

3

2

1

5

Hampton GC60 Cast Pellet Stove Owner’s Manual