INSTALLATION

OPTIONAL REMOTE

CONTROL

Use the FPI Remote Control Kit approved for
this unit. Use of other systems may void your
warranty.

The remote control kit comes with a hand held
transmitter, a receiver and a wall mounting
plate.

1) Choose a convenient location on the wall

to install the receiver and the receptacle
box (protection from extreme heat is very
important). Run wires from the fi replace to
that location. Use Thermostat Wire Table.

2) Connect the two wires to the gas valve. See

wiring diagrams. Optional wall switch GT/
GTM using wire 0.584.907

FINAL CHECK

Before leaving this unit with the customer, the
installer must ensure that the appliance is fi ring
correctly. This includes:

1) Clocking the appliance to ensure the correct

fi ring rate (rate noted on label) at 15 minutes.

2) If required, adjusting the primary air to ensure

that the fl ame does not carbon. First allow
the unit to burn for 15 min. to stabilize.

3) Check for proper draft.

CAUTION

Any alteration to the product that
causes sooting or carboning that
results in damage to the exterior
fascia is not the responsibility of
the manufacturer.

CAUTION

Do not connect the millivolt

remote control wires for

to the 120V wires.

3) Install 3 AAA alkaline batteries in transmitter

and 4 AA alkaline batteries in the receiver.
Install the receiver and its cover in the wall.
Switch the remote receiver to "remote"
mode. The remote control is now ready for
operation.

OPTIONAL WALL

THERMOSTAT

A wall thermostat may be installed if desired,
follow the wiring diagram below. FPI offers an
optional programmable thermostat but any
250-750 millivolt rated non-anticipator type
thermostat that is CSA, ULC or UL approved
may be used.

14 GA.
16 GA.
18 GA.
20 GA.
22 GA.

50 Ft.
32 Ft.
20 Ft.
12 Ft.

9 Ft.

Recommended Maximum Lead Length

(Two-Wire) When Using Wall

Thermostat (CP-2 System)

Wire Size Max. Length

Thermostat Wire Table

CAUTION

Do not connect the millivolt wall

thermostat wires

to the 120V wires.

BATTERY INSTALLATION

1) 4 AA batteries must be installed in the battery pack to operate the burner switch.

2) Install 2 AA batteries per side and connect as shown below.