INSTALLATION

MODIFICATION OF MONTIGO 28F-2 OR 28-F

1. Turn off unit, disconnect gas and power.

2. Remove Top and Bottom Louvers.

3. Remove Screen Mesh (See Diagram 7.1) or Bifold Doors.

Diagram 7.1

Diagram 7.4

Diagram 7.3

Diagram 7.5

Diagram 7.2

4. Remove Logs and Sand from Sand Pan.

5. Remove Front Bar. (See Diagram 7.2).

6. Disconnect Pilot Gas Line and Pilot Thermopile from the Valve.

Disconnect Thermostat wires from valve.

7. Disconnect Valve from the Main Burner Line (See Diagram 7.3).

8. Unscrew left and right side nuts, under the fi rebox, holding down

the Sand Pan. (see Diagram 7.5)