Regency

®

E18 Gas Fireplace Insert

33

INSTALLATION

5 1/4"

133mm

8 3/16"

208mm

2 1/8"

54mm

C

Firesong 220N Firebox

E18 Insert

Leg heig

Leg Setting / Outer Shell Position

5 - 3/16"

[132mm]



PP



'

(,QVHUW

)LUHVRQJ1)LUHER[

9HQWVRQFHQWHU

'(7$,/'

6&$/(

$GDSWRU3ODWH

)DVWHQHU6HWWLQ



PP



/HJ6HWWLQJ2XWHU6KHOO3RVLWLRQ

)OH[$GDSWRU/HQJWK

&ROODU3ODWH6HWWLQJ9HQWSRVLWLRQ

E18 Install Specifi cations

See Installtion of E18 into Existing Units for General Installation Guidance.

This install of the E18 uses Vent Connection Type A..

The Length of 4" Flex needed is 1-15/16" semi-expanded. Secure fl ue adapter top plate to under side of existing fi rebox using 4 self tap-

ing screws.

1. Loosen 2 x philips screws on both right and left legs.

2. See above diagram below for required leg setting.

3. Install with supplied phillips screws to prepunched holes and tighten previ-

ous screws that were loosened in Step 1.

4. Keep left side leg loose until outer fi rebox is in position in ZC box - to allow

adjustment of gas line.

Firesong 22N faceplate is an outside fi t, if the front metal face

of the 220N is covered with stone or tile - a custom faceplate
will be required.

The following measurements of the 220N metal face will be

visible if no stone or tile is covering it. If this metal face is vis-
ible, the standard Faceplate (6161-920) will fi t.

Set to this

hole

Set to this

hole

Right side shown

Secure top plate to fi rebox w/4 screws.

Secure vent slide plate to fl ex pipe with 4

screws

3"

(76mm)

3"

(76mm)

1"

(25mm)

Firesong 220N

Front Facing measurements

Note: this measurement
is above lower area