L540PB-2 / HZI540PB-2 Direct Vent Gas Insert

INSTALLATION

VENTING

THE APPLIANCE MUST NOT BE

CONNECTED TO A

CHIMNEY FLUE SERVING A

SEPARATE SOLID FUEL

BURNING APPLIANCE.

This appliance is designed to be attached to a
3" intake and a 4" exhaust aluminium fl ex vent.
The fl ue length must be a minimum length of 8 '
(2.44m) and a maximum of 35' (10.7m). See chart
for minimum distances from roof. Periodically check
that the vent is unrestricted.

Masonry chimneys may take various contours which
the fl exible liner will accommodate. However, keep
the fl exible liner as straight as possible
, avoid
unnecessary bending.

GAS CONNECTION

1) If the appliance is to be installed into an existing

chimney system, thoroughly clean the masonry
or factory built fi replace.

2) The appliance is provided with an opening on

the left hand side of the control compartment.
A 3/8" NPT gas supply pipe must be brought
near this inlet hole.

3) Locate the center point where the vent will pass

through the chimney above the appliance. Move
the appliance into the exact location where it is
to be installed. Ensure that the Insert is level.

4) Do not cut any sheet-metal parts of the fi re-

place, in which the gas fi replace insert is to
be installed.

5) If the factory-built fi replace has no gas access

hole(s) provided, an access hole of 1-1/2"
(37.5mm) or less may be drilled though the
lower sides or bottom of the fi rebox in a
proper workmanship like manner. This access
hole must be plugged with a non-combustible
insulation after the gas supply line has been
installed.

Air Intake pipe and exhaust must be attached to
the inlet and exhaust collars of the appliance with
a minimum of three screws per pipe.

GAS CONNECTION WARNING:

Only persons licensed to work

with gas piping may make the

necessary gas connections

to this appliance.

3" Air

Intake

4" Exhaust

Flue

The Air Intake and exhaust pipes must be attached
to the inlet and exhaust collars of the termination
cap with a minimum of three screws per pipe.

Part #

Description

948-305

3" Flex - 35 ft. (Air intake)

948-336

4" Flex - 35 ft. (exhaust)

946-588

Co-linear DV Vertical Termination Cap

NOTE: Flashing should be securely
fastened to the chimney.