14

L540PB-2 / HZI540PB-2 Direct Vent Gas Insert

INSTALLATION

LEVELING LEG ADJUSTMENT

The L540PB / HZI540PB inserts are equipped with 2 levelling legs that are accessible while the appliance is in its fi nal installation position. The unit

can be adjusted up to 5/8" (16mm). The faceplate must not be installed to do this adjustment, if installed, remove faceplate.

Remove left and right inner panels by sliding them forward. The rear levelling bolts are located in the back corners of the fi rebox and can be adjusted

using a 7/16" wrench. Rotate the bolts clockwise to raise the rear of the fi rebox.

When the appliance is in position, adjust the bolts to level the appliance, making sure that the appliance is also level and is sitting on both bolts to

prevent rocking.

Leveling Bolts