Bryant TSTATBBPB501 User Manual

Page 15

Advertising
background image

Advanced Setup

Page 14

Select the display back-
light always On, or Off
after 8 seconds.

On

Off

Select thermostat
operation in degrees
Fahrenheit or Centigrade.

C

F

Press the Mode button.

While holding the Mode, press the Fan

button for 2 seconds to leave the Setup

screens. If no buttons are pressed, the

display will leave the setup screens after

30 seconds.

Select the cycles per
hour limit.
d=cycles per hour
limit defeated.
d1=d + defeat 5 min.
Compressor lockout.

(d, d1, 2 - 6)

6

8

Cy

Setup

Press

Press

MODE

MODE

Setup

F

I0

Setup

L I

9

ON

FAN

MODE

Advertising