Input / output connections – Vicor VIPAC Array CONFIGURATION GUIDE User Manual

Page 5

Advertising
background image

4

v

i

c

o

r

p

o

w

e

r

.

c

o

m

/

v

c

a

d

Pin#

Funct.

1-4

– Vin

5-7

+Vin

8

NC / PR bus

9

PE protective earth

10

Neg. enable

11-13

– Vin

14-17

+Vin

18

NC / PR bus

19

PE protective earth

20

Pos. enable

VA-J and VA-K configurations only
(300 and 375 Vin single Maxi or single Mini)

Pin#

Funct.

1-3

– Vin

4-6

+Vin

7

NC

8

NC / PR bus

9

PE protective earth

10

Neg. enable

11-13

– Vin

14-16

+Vin

17

NC

18

NC / PR bus

19

PE protective earth

20

Pos. enable

Input / Output Connections

1

11

20

10

Mating Connector

Vicor part #

Amp part#

Housing

24795

2-794657-0

Contacts

24796

1-106529-2

Kit

24828

J1

Input Connector
(View looking into J1)

Solder

Pin #

Pad

Function

1

– Vout

Rd

Trim Down

SC

Secondary Control

Ru

Trim Up

3

+ Vout

Consult design calculator for Rd/Ru trim resis-
tor values located at vicorpower.com

Factory installed Micro LugMate

Ru

SC

Rd

1

3

1

5

*Removable

Jumper

*Removable

Jumper

1

5

J4

1

5

Discrete Output

J1

J1

Factory installed Mini/Maxi LugMate

3

1

3

1

3

1

Shown with the output(s) of two modules
connected in parallel using factory installed
bus bar.**

To disable output(s) apply +5 Vdc between pins
10 and 20 in the polarity indicated

*

P/N 16385

1

5

+S

–S

Parallel Output

Pin # Conn.

Function

Mating Conn.

1

– Vout

J4-1

– Vout

J4-2

– Sense

J4-3

Secondary Control

P/N

16385

J4-4

+ Sense

J4-5

+ Vout

5

+ Vout

*Removable jumpers in J4 are factory installed for local
sensing. For remote sensing the +Sense pins should be
tied to the same point on the +Out power bus;
the -Sense pins should be tied to the same point the -
Out power bus.