Electrical connection, Fig 9: connection diagram – WarmlyYours Lava User Manual

Page 9

Advertising
background image

ELECTRICAL CONNECTION

The heater is designed for permanent connection to a

suitable room thermostat. Please refer to the instructions

of the room thermostat.

ATTENTION: If the power cord of the unit is damaged, it

must be replaced immediately.

Fix mounted thermostats should be mounted next to the

heated room’s entry door at 4’ or 1.3m height from floors.

An alternate location is on an interior wall, not subject to

direct sunlight. The thermostat should not be installed

within 3 feet of the LAVA. Power the thermostat with a

GFCI Protected Circuit.

The device is connected with the supplied connector to

a junction box supplying the AC power supply. If a longer

cable is required, it can be replaced by longer one, 18 AWG

or Larger.

HEATING
The heater is controlled by the externally mounted

thermostat.

GROUNDING
The heater is for use with 120 volts. The green-yellow

grounding of the cord must be connected to a permanent

ground inside the junction box.

Installation and Usage Instruction | LAVA® Design Glass Radiator

8

BLACK
WHITE

GREEN GROUND

2” x 4” ELECTRICAL BOX

2” x 4” ELECTRICAL BOX

LAVA Radiant Panel

HOT

LOAD

(black or blue)

POWER

SWITCH

GFCI

Protected

Circuit

Hot

Black

Hot

Black

Neutral

White

Neutral

White

Ground

GROUND

(green or yellow)

NEUTRAL LOAD

(white or brown)

THERMOSTAT

ELECTRICAL BREAKER PANEL

Load

Line

Fig 9: Connection diagram