Installation instructions, Activate perimeter adhesive, Install power supply – WarmlyYours FeelsWarm® Countertop Heating User Manual
Page 9
5. ACTIVATE PERIMETER ADHESIVE
Once the heating element is attached, the high-bonding adhesive must be fully activated.
IMPORTANT: The heater has a perimeter bonding adhesive that provides the premium adhesion of the edges
of the heating element to the stone. Press extra hard within the area within 1” of the perimeter to secure the
high-bond edges.
IMPORTANT: To avoid damage to connection points, do not press hard on the wire connection pad area.
NOTE: The bonding adhesive takes 72 hours to reach the full bond strength. Do not attempt to peel the heater off the
stone to test the adhesion.
6. INSTALL POWER SUPPLY
Connect the power cord to the transformer, then connect the three units together as shown.
The heater will draw up to between 1/2 and 2 amps at 120V depending upon the size of the heater. (For reference, a toaster
typically will draw up to 12.5 amps). Traditional home circuit lines will be wired for 15 amps. If other significant current-
drawing devices use the same circuit as the outlet the heater is plugged into, and the circuit breaker limit will be exceeded,
consult a licensed electrician for a permanent solution.
IMPORTANT: If the WarmlyYours FeelsWarm® system to be installed involves multiple transformers and/or
multiple heating elements, each transformer plug and each heating element cable will have a numerical tag
with matching code numbers. It is extremely important that the correct transformer plug is plugged into its
corresponding heater cable.
8
Approx. 72”
Thermal Control Unit
Approx. 60”
Approx. 42”
Approx. 24”
Heating Element
Transformer
To 120V House Outlet
Installation Instructions
SECTION 2