WARNING: To avoid damaging your floor, follow your floor supplier’s recommendations regarding floor
temperature limits.
The minimum and maximum floor temperature limits are 41°F (5.0°C) and 82°F (28.0°C) by default. To
modify these limits, proceed as follows:

n

Switch the thermostat to Off.

o

Press and hold the

button.

p

Switch the thermostat back to On.

q

Release the

button when the minimum temperature limit (FL:LO) appears.

r

Set the minimum temperature limit using the

buttons.

s

Press the

button to display the maximum temperature limit (FL:HI).

t

Set the maximum temperature limit using the

buttons.

u

Press Mode/Ret to return the thermostat to normal display.

NOTE: The thermostat will automatically return to normal display if no button is pressed for
60 seconds.

Floor temperature limits (AF mode only)