WarmlyYours SCV-DUAL User Manual

Page 4

Advertising
background image

Snow Switch

®

Model LCD–8 Aerial Snow Controller, 100 – 240 VAC

24782 Rev. A 03/13

(800) 234-4239

http://www.networketi.com

3 of 14

Environmental Technology, Inc.

Safety

Make all electrical connections in compliance with the National Electrical Code

(NFPA 70) and local electrical code. If you have questions concerning the installation

or application, contact Customer Service.

Abnormal Odor or Smoke

In the event of smoke or a burning or abnormal odor, immediately interrupt

power to the unit by unplugging the unit or by turning off the circuit breaker protect-

ing the unit.

Electrical Shock / Fire Hazard

Even when the snow melting elements are disconnected, as long as the circuit

breaker is on and power is running to the unit, voltage is still being applied to the

system’s yellow leads. Therefore, never touch the ends of the yellow leads or let the

two leads touch each other. Do not let the two yellow leads contact any component

inside the unit.

Any installation involving electric heater wiring must be grounded to earth to

protect against shock and fire hazard. Suitable ground fault detection and interrupting

systems must be in use at all times to reduce shock and fire hazard and to protect

equipment.

Electric wiring to heating elements must be installed in accordance with National

Electrical Code (NEC) requirements and all other local and applicable electrical codes

and any third party standards. Follow the installation instructions contained herein and

those provided by the heater manufacturer.

Use a GFEP (Ground Fault Equipment Protection) circuit breaker on each branch

circuit connected to the ice melting system. Clearly label each circuit breaker with its

function. This is vitally important when there is more than a single point of disconnect.

Size the circuit breaker in accordance with the size of the expected load. The

maximum current load for the LCD-8 is 16 Amp resistive. This product is intended for

use in residential or light commercial applications.

Make certain that the heater shield is properly grounded. Failure to do so may

result in damage to the equipment or fire.

Following installation and prior to beginning system operation, refer to and perform

the Post-Installation Tests (page12) described in this manual.

Additional Information

More information is made available regularly through our website,

www.networketi.com. Please visit us online for Data Sheets, Manuals, White Papers,

technical articles, and more. The most current and up to date version of this and

every other manual for our products can be found in Acrobat (PDF) format to view

online or to print. This is to assist you in installing and using our products to the

best effect possible. If you have any comments about this or any other product from

Environmental Technology, Inc., please contact us.

Contacting Environmental Technology, Inc.

For assistance, contact Customer Service. Office hours are from 8:00 AM until

5:00 PM ET.

Voice:

(800) 234-4239 (USA and Canada) or (574) 233-1002 (elsewhere)

Fax:

(888) 234-4238 (USA and Canada) or (574) 233-2152 (elsewhere)

E-mail:

[email protected]

Mail:

Environmental Technology, Inc.

1850 North Sheridan Street

South Bend, IN 46628

Advertising