Snow Switch

®

Model LCD–8 Aerial Snow Controller, 100 – 240 VAC

24782 Rev. A 03/13

(800) 234-4239

http://www.networketi.com

6 of 14

Environmental Technology, Inc.

Ш 4.60”

Ш 117mm

6.35”

161mm

0.50”

13mm

0.75”

29mm

Mount rigidly in an upright position,
as shown, at a height above ground
as necessary to discourage
animal damage and vandalsim.

Be certain sensor grid is in a clear
and open area identical to that
requiring melting and exposed
to falling snow.

Weatherproof conduit body

or junction box supplied by customer.

Make all threaded joints weathertight.

Insulate splices with wire nuts.

Ambient air temperature sensor

Cool this area per instructions when testing

Designed to be mounted using PVC conduit

using either 3/4" inserted

into the flange (0.82"/21mm ID)

or, with a coupler, 1" mounted

around the flange (1.32"/34mm OD).

Consider PVC adaptor if using metal conduit.

Sensor grid

Figure 3. LCD-8 installation

Installation

With user-supplied hardware, mount the LCD-8 securely in an upright posi-

tion (sensor grid at top; see Figure 3) in a clear and open area typical of the area to

be melted, either above the roof line or removed from the building and exposed to,

rather than protected from, falling snow.

Avoid overhead trees, shrubs, wires, eaves, etc., and falling or blowing debris.
Avoid vehicle and foot traffic. Do not create a safety hazard.

Avoid exposure to artificial heat sources and excessive shock and vibration.

The LCD-8 also should be positioned at a height above ground that reduces,

eliminates or discourages damage caused by animals or vandals.