Accessories—mm (inches) (continued), Fiber optic cable selection, Straight mounting bracket #60 6 – Rockwell Automation 42KL MiniSight User Manual

Page 6: Apertures, Quick-disconnect cordsets

Advertising
background image

Accessories—mm (inches) (continued)

R 24

(0.95)

52

(2.04)

2 Places

70

(2.78)

Straight Mounting Bracket #60--2656

1.5

(0.06)

42.4

(1.67)

R 15

(0.59)

15.7

(0.62)

30_

3 Places

18.5

(0.73) Dia.

29

(1.14)

12.7

(0.50)

53

(2.10)

4.6

(0.18)

4 Places

Apertures

889R--F3AEA--2

Heavy duty 1.8m (6ft) with

protective shield

889R--F3AEA--5

Heavy duty 3.6m (12ft) with

protective shield

889R--F3AEA--10 Heavy duty 6m (20ft) with

protective shield

Snap-on apertures for Transmitted Beam applications are avail-

able for MiniSight sensors to detect small objects. Select an ap-

erture slot size that will be blocked by the object being detected

for best results. An aperture should be placed on both the source

and receiver units for proper operation.
1mm slotted aperture, Qty. 20: #60--2673

2mm slotted aperture, Qty. 20: #60--2674

4mm slotted aperture, Qty. 20: #60--2675

Aperture assortment, Qty. 4 each—1mm, 2mm, 4mm: #60--2676

Snap-on Aperture

889D--F4EC--2

Heavy duty 2m (6.6ft) with

protective shield

889D--F4EC--5

Heavy duty 5m (16.4ft) with

protective shield

889D--F4AC--2

General purpose 2m (6.6ft)

nonshielded

889D--F4AC--5

General purpose 5m (16.4ft)

nonshielded

Quick-Disconnect Cordsets

All quick-disconnect versions of DC

MiniSight sensors use 4-conductor

micro or pico style quick-disconnect

cordset. These cables are PVC

insulated and are supplied with

gold-plated female contacts and

nickel-plated brass hardware.

AC/DC MiniSight sensors with

quick-disconnect use 3-conductor

micro style quick-disconnect cables.

These cables are PVC insulated and

are supplied with gold-plated female

contacts and nickel-plated brass

hardware.

DC MiniSight Sensors

AC/DC MiniSight Sensors

Catalog

Number

DC Quick-Disconnect

Cable Description

Catalog

Number

DC Quick-Disconnect

Cable Description

18mm Mounting Nut

(supplied with sensor)

Catalog number 75012--097

max torque = 10in/lbs

Fiber Optic Cable Selection

Glass Fiber Optic Cables

Plastic Fiber Optic Cables

Sensing Mode

Glass Fiber Diameter

Typical Fiber Model

Maximum Range

Sensing Mode

Glass Fiber Diameter

Typical Fiber Model

Maximum Range

Diffuse

3.1 (0.125)

43GR--TBB25SL

38 (1.5)

Diffuse

1 (0.040)

43PR--NES57ZS

31 (1.2)

1.1 (0.046)

43GR--TFS10ML

21 (0.8)

0.5 (0.020)

43PR--NGS53ZM

12.7 (0.5)

Transmitted Beam

3.1 (0.125)

43GT--TBB25SL

457 (18)

Transmitted Beam

1 (0.040)

43PT--NJS56FS

127 (5)

1.1 (0.046)

43GT--TFS--10ML

152 (6)

0.5 (0.020)

43PT--NBS52FM

38 (1.5)

Hundreds of other fiber optic cabes are available. Consult the Allen-Bradley Fiber Optic Cable addendum catalog, publication C114--CA004A--EN--P.

Advertising