Rockwell Automation 1326AB_AB-MOD-G Air-Over Blower Option User Manual

1326ab air -over blower option, Allen-bradley instructions

Advertising
background image

ALLEN-BRADLEY

Instructions

1326AB Air -Over
Blower Option

(Cat. No. 1326AB-MOD-G3, G4)

Objectives The purpose of this publication is to provide the steps needed to properly

install the Ai r -Over Blower option (1326A-MOD-G3, G4) on 1326AB AC
Servomotors.

Description The Ai r -Over Blower option provides ai r -over cooling for up to 30% more

torque output on 1326AB “C” series AC servomotors.

Two blower kits are

available:

n

The “G3” kit is designed for all “C” series motors except those with rear
mounted encoders.

n

The “G4” kit is available for all “C” series motors including those with
rear mounted feedback devices (encoders, dual resolvers, etc.).

Each kit consists of an impedance protected fan (UL recognized, CSA
approved), housing, grill guard and necessary hardware.

The following table illustrates the operational improvements realized when
the kits are installed on typical motors.

Table A
Performance Improvements with the Blower Kit

Motor Cata-
log Number

1326AB-C2E

1326AB-C4B

1326AB-C2C

RMS Cont.
Torque

1

lb.-in. (N-m)

210 (23.7)

420 (47.5)

210 (23.7)

Continuous
Amperes
A

33.2

38.2

23.3

RMS Cont.
Torque

1

lb.-in. (N-m)

285 (32.2)

505 (57.1)

285 (32.2)

Continuous
Amperes

2

A

45.0

45.0

31.6

Motor without Blower Motor with Blower

1

at 4 0

°

C ambient.

2

Amplifier available current may limit actual torque improvement. Continuous output cannot exceed

45A.

Advertising