1326AB Air-Over Blower Option

Instructions

2

The following specifications apply to either kit.

Specifications

Input Voltage

220/240V AC, 50/60 Hz., single-phase

Line Amperes

0.15 / 0.14

Locked Rotor Amperes

0.23 / 0.23

Fan Output

240 CFM

Air Inlet Clearance

6 inches (152.4 mm)

Weight

4 lbs. (1.81 kg)

Important: The 1326AB-MOD-G3 and G4 option kits must not be used in
environments requiring IP65 protection.

Installation

The following steps provide the information needed to properly install the
Air-Over Blower option. Refer to Figure 1 for further information.

ATTENTION: To avoid a shock hazard, assure that all power
to the controller has been removed before performing the
following.

!

1326AB-MOD-G3

1. Assure that all power to the controller/motor has been removed.

2. Orient the blower housing as shown in Figure 1.

3. Secure the housing to the motor using the supplied standoffs and

screws.

4. Connect 240V AC power to the leads of the blower.

5. Check operation.

1326AB-MOD-G4

1. Assure that all power to the controller/motor has been removed.

2. Grasp the blower housing and spread it slightly, while sliding it over

the shaft end of the motor.

3. Continue sliding the housing on until it meets the front flange of the

motor. When completely installed, the housing will surround the motor.

4. Align one of the five metal standoffs between the two holes on either

side of the housing. Repeat for the remaining standoffs.

5. Connect 240V AC power to the leads of the blower.

6. Check operation.