Epic Connector or Plain Cable Connections

Motor Application Data

Maximum Safe Speed

The speeds given in

Table B

are the maximum mechanically safe

operating speeds for frames with standard construction. These speeds
must not be exceeded under any condition. Motor control must hold
the maximum speed under any load condition including no-load
within the maximum safe speed. Drive systems whose design
characteristics inherently prevent the AC motor from exceeding the
motor maximum safe operating speed must prevent the motor from
exceeding the maximum safe speed if a single component failure
should occur.

Table B
Maximum Safe Speed

With special construction maximum safe speed may differ from the
above values. In all cases, the maximum safe speed is indicated on the
motor nameplate.

Important: Normal operating speeds must be limited to those listed in

order to meet nameplate rating and assure validity of
warranty.

Pin

Signal

Color

Pin

Signal

Color

1

Common

Black

6

5-15V

Red

2

B

Green

7

B (NOT)

Yellow

3

A

Blue

8

A (NOT)

Gray

4

Z

Violet

9

Z (NOT)

Orange

5

No Connection –

10

Shield

Braid

!

ATTENTION: The machinery builder and/or user are
responsible for assuring that all drive train mechanisms, the
driven machine, and process material are capable of safe
operation at the maximum speed at which the machine will
operate. Failure to observe these precautions could result in
personal injury.

Frame Diameter

Maximum Safe Speed

L180

7200 RPM

L210

5000 RPM

L250

5000 RPM

L280

5000 RPM

L320

4000 RPM

L360

3750 RPM

L400

3750 RPM

L440

2700 RPM