Rockwell Automation 1394-FK10TS_FK22TS Fan Kit Installation Instructions User Manual

Page 6

Advertising
background image

6 1394 Fan Kit

Publication 1394-IN067A-EN-P — January 2005

Figure 4
Locating 24V dc Connections (22kW system modules)

2. Label and remove the 24V dc logic power wiring from the system

module.

3. Determine the positive 24V dc supply wire and align the red wire

from the fan kit to the +24V side.

4. Determine the negative 24V dc supply wire and align the black wire

from the fan kit to the -24V side.

5. Insert and tighten the 24V dc supply wires (and fan wires) as

described in the table below (system module polarity is not
specified).

IMPORTANT

The desired direction of air flow is upward. If fan
is wired backwards, air flow will be downward.

System Module

24V dc Input
Connections

Torque Value

1394C-SJT05 and -SJT10

J1-1 and -2

0.56 - 0.62 N-m
(5.0 - 5.6 lb-in.)

1394C-SJT22

W1 and W2

24V dc Logic Power Connections

(W1 and W2)

1394C-SJT22-

x-xx

System Modules (front view)

Advertising