Encoder data, Encoder outputs – Rockwell Automation 1398 F-Series Brushless Servo Motor Manual User Manual

Page 9

Advertising
background image

Encoder Data

Encoders are factory aligned and must not be adjusted outside the factory.

Encoder Outputs

Encoder Phase-to-Neutral and Phase-to-Phase Waveforms

ENCODER SPECIFICATIONS

Line Count

2000 (1)

Supply Voltage

5 VDC

Supply Current

250 mA max.

Line Driver

26LS31

Line Driver
Output

TTL

Index Pulse

F-2000 and F-3000 Series when key faces 180

o

±10 away from the connectors

F-4000, F-6000 and F-8000 Series when key faces the connectors (0

o

±10)

(1) Standard line count before quadrature

1

0

A

B

I

I

B

A

90°±22.5°

ENCODER OUTPUT

WAVEFORMS RESULT FROM CW SHAFT ROTATION

(CLOCKWISE AS VIEWED FACING THE SHAFT EXTENSION)

0°0±20°

ABS

R-N

S-N

T-N

INDEX

PHASE TO NEUTRAL

HALL A

HALL B

HALL C

R-S

PHASE TO PHASE

NOTE: Hall and ABS signals are in electrical degrees.

For 4 pole commutation, 360° mechanical = 720° electrical.

For 6 pole commutation, 360° mechanical = 1080° electrical.

For 8 pole commutation, 360° mechanical = 1440° electrical