All parameters are specified at 5V, 3A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless noted otherwise.

Rockwell Automation Publication 1606-RM019A-EN-P — March 2014

9

Bulletin 1606 Switched Mode Power Supplies

9. Functional Diagram

Fig. 9-1 Functional diagram

Input Fuse
&
Input Filter

L
N

Output Over-

Voltage

Protection

Input
Rectifier
&
Inrush
Limiter

Power

Converter

Output

Voltage

Regulator

+

-
-

Output

Filter

V

OUT

DC

on

PE

10. Front Side and User Elements

Fig. 10-1 Front side


A Output Terminals
Screw

terminals,

Dual terminals for the negative pole allows an easy grounding of the output voltage.

+ Positive output

- Negative (return) output


B Input Terminals
Screw

terminals

L Phase

(Line)

input

N

Neutral conductor input

PE (Protective Earth) input


C DC-on LED (green)

On when the voltage on the output terminals is > 2V


D Output voltage potentiometer

Turn to set the output voltage. Factory set: 5.1V