5. Secure the fan to the fan housing with two M4 screws and nuts using

1.6 N-m (14 in.-lbs) of torque.

Figure 8
Securing the Fan to the Fan Housing

6. Align the fan housing to the axis module.
7. Plug the fan into the axis module.

Figure 9
Fan Plug Attached to the Axis Module

8. Slide the fan housing back into place.
9. Secure the fan housing with two M3 x 6 mm screws using 0.70 N-m

(6 in.-lbs) of torque to the axis module.