Rockwell Automation 1394-AM50_AM75 Replacing the 10 and 15 kW Axis Module User Manual
Page 4
Rockwell Otomasyon Ticaret A.Ş., Kar Plaza İş Merkezi E Blok Kat:6 34752 İçerenköy, İstanbul, Tel: +90 (216) 5698400
Publication 1394-5.15 - September 1998
74102-272-01
Copyright © 1998 Rockwell Automation, Inc. All rights reserved. Printed in the U.S.A.
5. Secure the fan to the fan housing with two M4 screws and nuts using
1.6 N-m (14 in.-lbs) of torque.
Figure 8
Securing the Fan to the Fan Housing
6. Align the fan housing to the axis module.
7. Plug the fan into the axis module.
Figure 9
Fan Plug Attached to the Axis Module
8. Slide the fan housing back into place.
9. Secure the fan housing with two M3 x 6 mm screws using 0.70 N-m
(6 in.-lbs) of torque to the axis module.
10. Place the axis module back into your 1394 system and apply power.
Nut
Nut
Screws
Fan Plug