Installing Your 1394 Drive Interface Module

11

Publication 1394-5.12 — December 1999

To wire the cable flying leads to the DIM cable connector:

1. Turn off the power to the system (i.e., 1394 system external drives

and other control hardware).

2. Look at the cable connector to make sure the terminal is open.

The figure below shows a terminal open and a terminal closed.

Figure 17
Open and Closed Terminal

3. Using the table below, follow the correct procedure for each

termination point:

4. Turn the clamping screw counter-clockwise several times with a

small, flat-head screwdriver to open the termination point.

!

ATTENTION: To avoid a shock hazard or personal
injury, verify that all power has been removed before
proceeding. This system may have multiple sources of
power. More than one disconnect switch may be
required to de-energize the system.

!

ATTENTION: To avoid hazard of electrical shock,
verify that all voltage on the capacitors has been
discharged before attempting to service, repair or
remove this unit. This product contains stored energy
devices. You should attempt the procedures in this
document only if you are qualified to do so, and are
familiar with solid-state control equipment and the
safety procedures in publication NFPA 70E.

Terminal open

Terminal closed

If the terminal is:

Do this:

Closed

Go to step 4.

Open

Go to step 5.