Replacement parts, Troubleshooting – BLACKHAWK! AUTOMOTIVE BH6221 User Manual

Page 6

Advertising
background image

REPLACEMENT PARTS

Available Parts: Please refer to the Parts drawing when ordering parts. Not all components of the jack are replacement
items, but are illustrated as a convenient reference of location and position in the assembly sequence.
When ordering parts, give Model number, serial number and description below. Call or write for current pricing:
SFA Company 10939 N. Pomona Ave. Kansas City, MO 64153, U.S.A. Tel:(816)891-6390 Fax:(816)891-6599
E-Mail:[email protected]

TROUBLESHOOTING

Possible Causes

Corrective Action

Symptom

Jack will not lift load

Jack will lift, but not maintain
pressure

Will not lift to full extension

• Release valve not tightly closed
• Air supply inadequate

• Fluid level low

• Fluid level low
• Air trapped in system

• Release valve not tightly closed
• Hydraulic unit malfunction

• Ensure release valve tightly closed
• Ensure adequate air supply

• Ensure release valve tightly closed
• Contact Blackhawk Tech. Service

• Ensure proper fluid level

• Ensure proper fluid level
• With ram fully retracted, remove oil

filler screw to let pressurized air
escape, then reinstall oil filler screw

Poor lift performance

Jack will not lower after unloading • Reservoir overfilled

• Ensure load is removed, then drain

fluid to proper level

6

LUBRICATION
1. A periodic coating of light lubricating oil to pivot points, axles and hinges will help to prevent rust and assure that

pump assemblies move freely.

2. When used on a daily basis, air pump should be internally lubricated before each use. Use only good quality air

tool lubricant. If no inline oiler is used, pour a teaspoon of air tool oil into the inlet of the air control valve. Simply
operate the jack using the air feature in order to fully distribute the oil.

CLEANING
Periodically check the ram for signs of rust or corrosion. Clean as needed and wipe with an oily cloth.

Note: Never use sandpaper or abrasive material on these surfaces !

STORAGE
Store the jack with ram fully retracted and air supply disconnected when not in use.

Advertising
This manual is related to the following products: