Mounting requirements – Rockwell Automation 1305 DYNAMIC BRAKES User Manual

Page 10

Advertising
background image

1305 Dynamic Brake

10

1305-5.11 May, 1999

TOP

DRIVE

AIR

FLOW

BRAKE

304.8mm

(12in.)

minimum

30m

(100ft.)

maximum

304.8mm

(12In.)

minimum

CAT

1305–MOD–KB005 SER A

BULLETIN 1305 DYNAMIC BRAKE DC POWER

INPUT

680–750 VDC. 2.5 ADC (RMS) BRAKE ON

A–B P\N 151076 REV 01

MADE IN U.S.A.

FOR USE WITH 380/460 VAC BULL. 1336 A.F. DRIVES

(OUTPUT) HEAT DISSIPATION

375 WATTS MAXIMUM

UNOBSTRUCTED

UNOBSTRUCTED

Mounting Requirements

Dynamic brake enclosures must only be installed in the vertical
position. Select a location using the following guidelines.

• Each dynamic brake enclosure must be mounted outside of any other

enclosure or cabinet and exposed to unrestricted circulating air for
proper heat dissipation. Allow a minimum of 304.8 mm (12 in.)
between brake enclosures and all other enclosures or cabinets
including the drive.

• The brake enclosure must be mounted within 30 m (100 ft.) of the

drive.

Recommended Brake Mounting Configuration

Advertising