Specifications spécifications, Wiring câblage verdrahtung cablaggio cableado, Technische daten specifiche especificaciones – Rockwell Automation 1492-IFMxxxx 8 and 16 Point Isolated Fusible Interface Modules with Extra Terminals User Manual

Page 4

Advertising
background image

Specifications
Spécifications

SURGE SUPPRESSION follow the literature recommendations of the PLC module being used.
SUPPRESSION DES SURTENSIONS se trouve à la suite de la littérature qui contient les recommandations relatives au module PLC utilisé.
ÜBERSPANNUNGSSCHUTZ Bitte beachten Sie die Dokumentationsempfehlungen für das jeweils benutzte SPS-Modul.
Per la SOPPRESSIONE DEI PICCHI TEMPORANEI, seguire le istruzioni riportate nella documentazione in dotazione al Modulo PLC utilizzato.
SUPRESIÓN DE SOBRETENSIÓN, siga las recomendaciones indicadas en la documentación del módulo PLC respectivo.

Wiring
Câblage
Verdrahtung
Cablaggio
Cableado

Reference Publications: Refer to 1770-4.1 and appropriate PLC I/O module installation manual.

2 Amps

12 Amps

Maximum Recurring Peak Voltage

Tension de crele réurrente maximale

Maximale periodische Hochstspannung

Tensione massima di cresta ricorrente

Voltaje de cresta iterativo máximo

600 V

p

For transients > 600 Vp use a UL recognized suppression device rated at 2.5 kV withstand.

Pour des transitoires > 600 Vp utilisez un dispositif de suppression certifié UL à 2,5 kV nominal de tenue.
Für Einschaltstöße > 600 Vp verwenden Sie einen UL anerkannten Entstörer, der bewertet wurde bei 2,5 kV standzuhalten.
Per transitori > 600 Vp usare dispositivo di soppressione riconosciuto da UL capace di sopportare 2,5 kV.
Para transitorios > 600 Vp use un dispositivo de supresión reconocido UL clasificado con 2,5 kV.

7.09 in. (180 mm) W

3.27 in. (83 mm) H

2.78 in (70.5 mm) D

4.72 in. (120 mm) W

3.27 in. (83 mm) H

2.78 in (70.5 mm) D

< 1.5 mA
< 1.5 mA

0

< 2.5 mA
< 2.5 mA

Indicator Circuit Current

Courant circuit voyants

Strom, Anzeigeschaltkreis

Corrente circuito indicatori

Intensidad del circuito de
indicadores

Voltage

Tension

Spannung

Tensione

Voltaje

Catalog No.

Référence

Bestell-Nr.

N. Catalogo

Referencia

Technische Daten
Specifiche

Especificaciones

1492-IFM20F-FS120-4

1492-IFM20F-FS240-4

1492-IFM40F-FS-4

1492-IFM40F-FS24-4

1492-IFM40F-FS240-4

1492-IFM20F-FS120-4

1492-IFM20F-FS240-4

1492-IFM40F-FS-4

1492-IFM40F-FS24-4

1492-IFM40F-FS240-4

85-132 VAC/DC

168-264 VAC/DC

0-264 VAC/DC

10-30 VAC/DC

168-264 VAC/DC

Current/Circuit

Courant/Circuit

Strom/Schaltkreis

Corrente/circuito

Intensidad/circuito

Current/Module

Courant/Module

Strom/Modul

Corrente/modulo

Intensidad/módulo

1.18 lb.

536 g.

5 - 95%

cULus (File: E10314, Guide No. NRAG)

Suitable for use in Class 1 Div 2 Groups A,

B, C and D Hazardous and Non-Hazardous

Locations.

Temperature Code = T3C at 60°C

CE: Compliant for all applicable directives

FM Class 1 Div 2 Groups A, B, C and D

Temperature Rating T3C = 60°C (J.I. 3000590,

all except relay modules)

0° C - 60° C

Dimensions

Dimensions

Abmessungen

Dimensioni

Dimensiones

Standards

Normes

Standards

Standard

Estándares

Catalog No.

Référence

Bestell-Nr.

N. Catalogo

Referencia

Operating Temperature Range

Plage températures de fonctionnement

Betriebstemperaturbereich

Limiti temperatura di funzionamento

Rango de temperatura de funcionamient

Approx. Shipping Weight

Poids d'embarquement approximatif

Ungefähres Versandgewicht

Peso approssimativo del carico

Peso aproximado al momento de
embarque

PN-28297
DIR 40063-383 (Version 11)

Printed in U.S.A.

WARNING

Explosion Hazard - substitution of components may impair suitability for Class I Division 2.
Explosion Hazard - Do Not Disconnect Equipment unless power has been switched off or the area is known to be Non-Hazardous.

Wiring diagrams are online at

www.ab.com/e-tools/

Les schémas et sont disponibles en ligne à l’adresse

www.ab.com/e-tools/

Die Schaltpläne finden und unter der Internet-Adresse

www.ab.com/e-tools/

Gli schemi di cablaggio sono illustrati, oppure online all'indirizzo

www.ab.com/e-tools/

Los diagramas de conexiones están en y se encuentran en-línea en

www.ab.com/e-tools/

NOTICE

REMARQUE

HINWEIS

NOTA

AVISO

Non-condensing

Sans condensation
Nicht kondensierend
Senza condensa
sin condensación

Power, input and output (I/O) wiring must be in accordance with Class I Division 2 wiring methods - Artticle 501-10(B)(1) of the National Electrical Code.

Operating Humidity

Humidité relative

Betriebsluftfeuchtigkeit

Umidità di esercizio

Humedad operativa

Advertising