NEMA

Size

Dimensions In Inches

(Amps) C D E F G H J K L M N P R

T

V

X Y

q

WITHOUT DOOR HARDWARE

30

1

3/8

1

3/16

2

1/4

1

7/16

5/8

8

1/2

1 1

1/16

15/32

7

3/16

9/32 1/4

2

1/8

4

31/32

2

1/16

2

9/16

1

1

/

16

1

3/8

7/8 1/4

9/16

4

5/16

1

1/2

60

6

3/8

1

3/16

2

1/4

1

7/16

5/8

8

1/2

1

1/16

15/32

7

3/16

9 /32

7/32

2

1/8

4

31/32

3

1/4

2

9/16

1

1/16

1

3/8

7/8

1/4

1

7/8

4

5/16

2

1 0 0

8

1/2

1

3/16

2

1/4

1

7 /16 5/8

8

1/2

2

15/16 15/32

7

3/16

9/32

3 / 8

2

1/8

7

1/64

8

9/64

2

9/16

1

1/16

1

3/8

7/8

1/4

3

21/64

4

11/16

5

200 9 1

1/4

2

3/8

1

11/16

11/16

1

11/8

2

15/16

13/16

9

1/2

11/32

33/64

2

9/32

7

1/16

10

13/32

2

1/2

1

1/8

1

3

/8 7/8

1/4

4

1/32

6

3/4

7

SMALL

INTERMEDIATE ENCLOSURES WITH DOOR HARDWARE

30

6

3/8

1

3/16

2

9/16

1

7/16 5/8

8

1/2

1

1/16

60

6

3/8

1

3/16

2

9/16

1

7/16

5/8

8

1/2

1

1/16

1 0 0

8

1/2

1

3/16

2

9/16

1

7/16

5/8

8

1/2

2

15/16

200 9 1

1/4

2

5/8

1

11/16 11/16

11

1/8

2

15/16

5/8

8

1/2

1

1/16

15/32

7

3/16

9/32

1/4

2

5/32

4

31/32

2

1/4

2

1/8

15/32

7

3/16

9/32

7

/32

2

5/32

4

31/32

3

1/4

2

1/8

15/32

7

3/16 9/32

3/8

2

5/32

7

1/64

8

9/64

2

1/8

13/16

9

1/2

11/32 33/64

2

5/16

7

1/16

10/32

2

1/8

LARGE ENCLOSURES WITH DOOR HARDWARE

15/32

7

3/16

9/32

1/4

2

1/4

4

31/32

2

3/4

1

9/16

15/32

7

3/16 9/32

7/32

2

1/4

4

31/32

3

1/4

1

9/16

15/32

7

3/16

9/32

3/8

2

1/4

7

1/64

8

9/64

1

9/16

13/16

9

1/2

11/32

33/64

2

11/32

7

1

/16 10

13/32

1

9/16

q

Minimum wiring space for the maximum wire size.

G U I D E L I N E S

Small Enclosures: 30” high or less with 2 or 3 point

latching. Intermediate Enclosures: 30” thru 48” high
with 3 point latching. Large Enclosures: Above 48”
high with 3 point latching.

I N S T R U C T I O N S

1. Select the dimension table(s) which applies to your

enclosure construction, door and door hardware
construction and/or disconnect type (fusible or un-

fused) and NEMA size.

2. Determine the enclosure flange width (Dimension

E), the disconnect mounting depth (Dimension C),

the enclosure’s length (Dimension B) and width
(Dimension A + D) to insure that the fabricated
enclosure is as large as these minimum values. NOTE:
The enclosure length is based upon the minimum
wire space (Dimension

at top and bottom re-

quired by N.E.C. The minimum enclosure opening


1

1/8

1

1/8

1

1/8

and depth will insure adequate space for mounting

the disconnect inside the enclosure and securing it to
the enclosure flange.

Refer to N.E.C. for required wire bending space
(Dimension “Y”). If wire or pressure connectors

other than those of ALLEN-BRADLEY are used, this
dimension should be adjusted accordingly. Values
specified for

will provide “S” distance as shown.

Any change in

will cause an identical change in

“S”.

Provide slot and mounting holes on the right-hand

flange as indicated. NOTE: Location of holes in enclo-
sure mounting plate for disconnect switch and fuse

block adapter plate can be determined from line
drawings on Page

4

.

Locate door catch using “P” and “T”. NOTE: With
enclosures using door hardware, disregard the door
catch supplied with disconnect and use door catch
furnished with door hardware. Refer to Page

6

for

additional door catch instructions.

-3-