Approximate dimensions, Unfused and fusible disconnect switches, Fusible disconnect switches only – Rockwell Automation 1494F Flange Mounted Disconnect Switches Instructions User Manual

Page 5: Remove nuts

Advertising
background image

APPROXIMATE DIMENSIONS

MA

Fuse

Class

a n d

Dimensions In Inches

ze

mps)

Clip

Type H J R

X Z AA AB AC AD AE AF AG AH AK AK

1

AL AM AN AP AR AS AT AU

Unfused

-

8

1/2

1

1/16

4

31/32

4

5/16

-

5/16 1/2

5

15

/

16

5

-

-

7

1/2 5/16 1/4 9/16

9

1/2

3

7/1615/16

-

3

3/4 3/4

3 3/4 3/4

30A-250V H, R 8

1/2

1

1/16

4

31/32

4

5/16

-

5/16 1/2

7

13/16

5

- -

7

1/2

5

5/161/4 9

/16 9

1/2

3

7/16

15

/16

1

7/8

2

11/32 -

3

3/4 3/4

60A-250V H, R 8

1/2

1

1/16

4

31/32

4

5/16

-

5/16 1/2

8

9/16

5 -

-

7

1/2

5

5/16 1/4 9/16

9

1/2

3

7/16 15/16

1

7/8

2

11/32 -

3

3/4 3/4

0 30A-600V

H, R 8

1/2

1

1/16

4

31/32

4

5/16

-

5/16 1/2

10

9/16

5

2

13/16

7

1/2

5

5/16 1/4

9/16 91/2

3

7/1615/16

1

7/8

2

11/32

-

3

3/4 3/4

60A-600V

H, R 8

1/2

1

1/16

4

31/32

4

5/16

-

5/16

1/2

1

11/16

5

- 3

5/16

7

1/2

5

5/16 1/4

9/16 91/2

3

7/1615/16

1

7/8

2

11/16

-

3

3/4 3/4

30A-600V J 8

1/2

1

1/16

4

31/32

4

5/16

-

5/16 1/2

7

13/16

5 -

-

7

1/2

5

5/16 1/4 9/16

9

1/2

3

7/16 15/16

1

7/8

2

11/32

-

3

3/4

3/4

60A-600V

J

8

1/2

1

1/16

4

31/32

4

5/16

-

5/16 1/2

7

15/16

5

-

-

7

1/2

5

5/16 1/4 9/16

9

1/2

3

7/16 15/16

1

7/8

2

11/32

-

3

3/4 3/4

Unfused

8

1/2

1

1/16

4

31/32

4

5/16 5/8 5/16 1/2

5

15/16

5

-

-

7

1/2

5

5/16 1/4 9/16 ,

9

1/2

3

7/16 15/16

1

7/8

2

11/32 1/8

3

3/4 3/4

30A-600V H, R 8

1/2

1

1/16

4

31/32

4

5/16 5/8 5/16 1/2

11

1/8

5 - 3

3/8

7

1/2

5

5/16 1/4 9/16

9

1/2

3

7/16

15

/

16

1

7/8

2

25/32

1/8

3

3/4 3/4

60A-250V H, R 8

1/2

1

1/16

4

31/32

4

5/16 5/8 5/16 1/2

9

1/8

5 -

-

7

1/2

5

5/16 1/4 9/16

9

1/2

3

7/16

15/16 1

7/8

2

25/32 1/8

3

3/4 3/4

0 100A-250V H, R 8

1/2

1

1/16

4

31/32

4

5/16

5/8

5/16 1/2

11

5/8

5 7

7/16

3

7/8

7

1/2

5

5/16 1/4 9/16

9

1/2

3

7/16

15

/16

1

7/8

2

25/32 1/8

3

3/4 3/4

60A-600V H,

R 8

1/2

1

1/16

4

31/32

4

5/16 5/8

5/16 1/2

1

1

5/8

5 3

7/8

7

1/2

5

5/16 1/4 9/16

9

1/2

3

7/16

1

7/8

2

25/32 1/8

3

3/4 3/4

100A-600V

H, R 8

1/2

1

1/16

4

31/32

4

5/16

5/8 5/16 1/2

13

5/8

5 7

9/16

5

7/8

7

1/2

5

5/16 1/4 9/16

9

1/2

3

7/16 15/16

1

7/8

2

35/32 1/8

3

3/4 3/4

60A-600V J 8

1/2

1

1/16

4

31/32

4

5/16

5/8 5/16

1/2

8

1/2

5 -

-

7

1/2

5

5/16

-

-

1/4

9/16

9

1/2

3

7/16

15

/16

1

7/8

22

5/32 1/8

3

3/4 3/4

100A-600A J 8

1/2

1

1/16

4

31/32

4

5/16

5/8

5/16 1/2

10

7/16

5 7

13/32

2

11/16

7

1/2

5

5/16 1/4 9/16

9

1/2

3

7/16 15/16

1

7/8

22

5/32 1/8

3

3/4 3/4

Unfused

- 8

1/2

2

15/16

7

1/64

4

11/1613/16

3/8 1/2

7

15/16

5

8

1/4

7

3/16 9/16 5/8

9

1/2

15/16

1

7/8

3

3/8 1/16

3

3/4

3/4

I

2

15/16

I

4

11/1613/16

I

9/16

100A-250V

H, R 8

1/2

7

1/64

3/8 1/2

13

13/16

5 8

5/16

3

1/2

8

1/4

7

3/16 5/8

9

1/2

3

7/16 15/16

1

7/8

3

3/8 1/16

3

3/4 3/4

200A-250V

H, R 8

1/2

2

15/16

7

1/64

4

11/1613/16 3/8 1/2

14

11/16

5 8

9/16

4

3/8

8

1/4

7

3/16 9/16 5/8

9

1/2

3

7/16 15/16

1

7/8

3

3/8 1/16

3

3/4 3/4

00 100A-600V H, R 8

1/2

2

15

/16

7

1/64

4

11/1613/16 3/8 1/2

15

13/16

5 8

7/16

5

1/2

8

1/4

7

3/16 9/16 5/8

9

1/2

3

7/16 15/16

1

7/8

3

3/8 1/16

3

3/4 3/4

200A-600V H, R 8

1/2

2

15/16

7

1/64

4

11/16 13/16 3/8 1/2

17

3/16

5 8

11/16

6

7/8

8

1/4

7

3/16 9/16 5/8

9

1/2

3

7/16 15/16

1

7/8

3

3/8 1/16

3

3/4 3/4

100A-600V J 8

1/2

2

15/16

7

1/64

4

11/16 13/16 3/8 1/2

12

5/8

5 8

9/32

2

5/16

8

1/4

7

3/16 9/16 5/8

9

1/2

3

7/16 15/16

1

7/8

3

3/8 1/16

3

3/4 3/4

200A-600V J 8

1/2

2

15/16

7

1/64

4

11/16 13/16 3/8 1/2

13

3/8

5 8

1/2

3

1/16

8

1/4

7

3/16 9/16 5/8

9

1/2

3

7/16 15/16

1

7/8

3

3/8 1/16

3

3/4 3/4

Unfused - 11

1/8

2

15/16

7

1/16

6

3/4

1

5/32 7/16 5/8

10

1/2

7

-

1

1

3/8

9

5/8 3/32

13/16

12

3/8

4

1/2

1

2 4

3/8 7/16

5

9/16 15/16

200A-250V

H, R 11

1/8

2

15/16

7

1/16

6

3/4

1

5/32 7/16 5/8

17

3/16

7

3

1/2

11

3/8

9

5/8 3/32 13/16

12

3/8

4

1/2

1

2

4

3/8 7/16

5

9/16 15/16

400A-250V

H, R 11

1/8

2

15/64

7

1/16

6

3/4

1

5/32 7/16 5/8

7

11

3/4

5 1

1

3/8

3/32 13/16

12

3/8

4

1/2

1

2 4

3/8 7/16

5

9/16 15/16

00 200A-600V H,

R 11

1/8

2

15/16

7

1/16

6

3/4

1

5/32 7/16 5/8

7

11

3/8

6 11

3/8

9

5/8 3/32 13/16

12

3/8

4

1/2

1

2 4

3/8 7/16

5

9/1615/16

400A-600V H ,

R 1

1/8

2

15/16

7

1/16

6

3/4

1

5/32 7/16 5/8

7

12 8 1

1

3/8

3/32 13/16

1 2

3 /8

4

1/2

1

2 4

3/8 7/16

5

9/16 15/16

200A-600V J 11

1/8

2

15/16

7

1/16

6

3/4

1

5/32 7/16 5/8

7 1

1

3/16

2

3

/16 1 1

3/8

3/32 13 /16

12

3/8

4

1/2

1 2 4

3/8 7/16

5

9/16 15/16

400A-600V J 11

1/8

2

15/16

7

1/16

6

3/4

1

5/32 7/16 5/8

7 11

5/8

3

1/2

11

3/8

9

5/8 3/32 13/16

12

3/8

4

1/2

1

2

4

3/8 7/16

5

9/1615/16

DISCONNECT SWITCH AND FUSE BLOCK KIT

INSTALLATION INSTRUCTIONS

Unfused and Fusible Disconnect Switches

1.

Remove nuts

and washers from flange plate.

2. Place the disconnect switch into the enclosure with

the operating handle in the “Off” position. Tilt the

assembly under the flange and at the same time

bring the handle through the slot provided.

3. Place flange plate studs through the holes in the

flange and mechanism frame while holding the
assembly against the under side of flange. Secure
assembly to flange.

4. Attach disconnect switch firmly to the enclosure

mounting plate surface. See line drawing Page 2

(Mounting hardware and spacers are furnished by

user).

Fusible Disconnect Switches Only

1.

Attach fuse clips provided with the fuse block adap-

ter plate kits to the disconnect switch terminals. For

100, 200 and 400 Amp clips see Form 1494F-01A.

2. Attach the fuse block adapter plate to the disconnect

switch mounting bracket.

3. Secure the fuse block adapter plate to the enclosure

mounting plate surface. See line drawing Page

2

(Bolts and spacers are furnished by user).

NOTE:

It is recognized that holes in the enclosure

mounting plate surface used to secure the discon-
nect and fuse block adapter plate can be located
previous to installation. Refer to line drawings on
Page

4

.

Advertising