All parameters are specified at 24V, 0.63A, 230Vac input, 25°C ambient and after a 5 minutes run-in time, unless noted otherwise.

4

Rockwell Automation Publication 1606-RM004A-EN-P - January 2014

Bulletin 1606 Switched Mode Power Supplies

3. AC Input

AC input

nom.

AC 100-240V

-15% / +10%, TN/TT/IT-mains

AC input range

85-264Vac

continuous operation

264–300Vac

<

0.5s

Allowed voltage L or N to earth

max.

300Vac

Input frequency

nom.

50–60Hz

±6%

Turn-on voltage

typ.

59Vac

steady-state value, see Fig. 3-1

Shut-down voltage

typ.

54Vac

steady-state value, see Fig. 3-1


AC 100V

AC 120V

AC 230V

Input current (rms)

typ.

0.34A

0.28A

0.17A

at 24V, 0.63A see Fig. 3-3

Power factor *)

typ.

0.52

0.51

0.44

at 24V, 0.63A see Fig. 3-4

Crest factor **)

typ.

3.45

3.53

3.94

at 24V, 0.63A

Start-up delay

typ.

700ms

700ms

700ms

see Fig. 5 2

Rise time

typ.

20ms

20ms

24ms

at 24V, 0.63A, see Fig. 3-2

Turn-on overshoot

max.

100mV

100mV

100mV

see Fig. 3-2

*)

The power factor is the ratio of the true (or real) power to the apparent power in an AC circuit.

**) The crest factor is the mathematical ratio of the peak value to RMS value of the input current waveform.


Fig. 3-1 Input voltage range

Fig. 3-2 Turn-on behavior, definitions

Turn-on

85V

Rated

input range

max.

500ms

V

IN

P

OUT

54V

300Vac

264V

Shut

-down

59V

Start-up

delay

Rise

Time

Overshoot

- 5%

Output
Voltage

Intput
Voltage

Fig. 3-3 Input current vs. output load at 24V

Fig. 3-4 Power factor vs. output load

0.7A

0.1

0.2

0.4

0

0

0.10

0.4A

Input Current, typ.

0.5

0.20

0.3

0.6

0.25

0.15

0.05

0.30

0.35

b

c

a

a) 100Vac

b) 120Vac

c) 230Vac

Output Current

0.7A

0.1

0.2

0.3

0.5

0.30

0.35

0.40

0.45

0.50

0.55

Power Factor, typ.

a) 100Vac

b) 120Vac

c) 230Vac

b

c

a

0.4

0.6

Output Current