Shaft Seal Kits

MS Connector Kits

Wire and Contact Sizing Recommendations

The following connector contact sizes and wiring gages are recommended for cabling to a motor.

Factory manufactured power cables and encoder cables are available in standard cable lengths of 10,
25, 50 and 75 feet (3, 7.6, 15 and 23 meters).

MOTOR SEAL KITS

MOTOR SERIES

PART NUMBER

SIZE

(Outside Dia x Inside Dia x Width)

H-2000

0041-5056

22mm x 12mm x 7mm (0.87” x 0.47” x 0.27”)

H-3000

0041-5065

35mm x 15mm x 7mm (1.40” x 0.59” x 0.27”)

H-4000

0041-5058

47mm x 20mm x 7mm (1.85” x 0.79” x 0..27”)

H-6000

0041-5059

80mm x 38mm x 8mm (3.15” x 1.50” x 0.31”)

H-8000

0041-5053-005

85mm x 45mm x 8mm (3.35” x 1.77” x 0.31”)

NOTE: Shaft seals are manufactured to millimeter dimensions. Inch dimensions are conversions from millimeters.

Shaft seals require a lubricant to reduce wear. Lubricant is provided with kit.

MOTOR POWER CONNECTORS

STRAIGHT

MOTOR SERIES

RIGHT ANGLE

9101-0325

(MS3106F18-4S)

H-2000 and H-3000

9101-0398

(MS3108F18-4S)

9101-0326

(MS3106F20-4S)

H-4000 9101-0399

(MS3108F20-4S)

9101-0327

(MS3106F24-22S)

H-6000 9101-0400

(MS3108F24-22S)

9101-0328

(MS3106F32-17S)

H-8000 9101-0401

(MS3108F32-17S)

BRAKE POWER CONNECTORS

ENCODER FEEDBACK CONNECTORS

STRAIGHT

STRAIGHT

9101-0330

(MS3106F12S-3S)

9101-0329

(MS3106F20-29S)

RIGHT ANGLE

RIGHT ANGLE

9101-0403

(MS3108F12S-3S)

9101-0402

(MS3108F20-29S)

POWER CONNECTOR

ENCODER CONNECTOR

MOTOR

CONTACT

AWG(mm

2

)

WIRE

AWG(mm

2

)

CONTACT

AWG(mm

2

)

WIRE

AWG(mm

2

)

H-2005

16 (1.5)

16 (1.5)

All H-Series:

16 (1.5)

24 (0.25) with

H-3007

Ultra Plus Series Drives

H-3016

22 (0.34) with

H-4030

12 (4.0)

Ultra Series 100-200 Drives

H-4050

14 (2.5)

H-4075

BRAKE CONNECTOR

H-6100

8 (8.6)

12 (4.0)

CONTACT

AWG(mm

2

)

WIRE

AWG(mm

2

)

H-6200

8 (10)

H-6300

16 (1.5)

18 (0.75)

H-8350

4 (21.6)

6 (16)

· Recommended minimum mechanical size.

· Local regulations should always be observed.

H-8500

· Sizes are recommended minimum values for 4 conductors

(R, S, T and GND).

· Wiring should be twisted.

· Local regulations should always be observed.

P0005

P0004

P0005

P0004

P0005

P0004

Advertising