A1 - a4 frame drives – Rockwell Automation 1336S PLUS II Analog Interface Inst. User Manual

Page 2

Advertising
background image

2

1336 PLUS II Analog Interface Option Board Installation

3. Set the DIP switches for desired configuration.

Each board will have one or two DIP switches depending on the
option selected. The first function (input or output) is configured
with the S1 DIP switch – the second function is configured with
S51. Using the table below, set the switch(es) for correct operation.

Important:

Due to different switch manufacturers, the individual
switches will be designated “A or 1” and “B or 2.” In
addition, switch positions will be indicated as “Off or
0” and “On or 1.”

S1 and S51 Configuration Settings

4. Install board using appropriate instructions for your drive.

A1 - A4 Frame Drives

A. Remove the HIM (or other option). Remove the four screws

securing the HIM mounting cradle.

B. Using the following figure, locate the appropriate slot for

installation. Remove any jumpers (from J9 or J10) present for
that slot.

C. Carefully align the option board (connector side down)

mounting holes with the standoffs. Press the board into posi-
tion until the mounting posts lock onto the board.

D. Replace the mounting cradle and any devices previously

removed. Replace drive cover.

E. Apply power and verify board presence by checking [Slot A

Option] or [Slot B Option] in the Analog I/O Group. The
board type should be indicated in the appropriate parameter.

Option

DIP Switch S1

DIP Switch S51

Function Mode

Switch Setting

Function Mode

Switch Setting

A/1

B/2

A/1

B/2

LA1

Output 0 10V

Off/“0”

Off/“0”

Configure Standard Analog Input 2 with J11.
Refer to User Manual for further information.

20mA On/“1”

On/“1”

LA2

Input 0

10V

Off/“0”

On/“1”

Input 1

10V

Off/“0”

On/“1”

20mA On/“1”

Off/“0”

20mA On/“1”

Off/“0”

LA3

Output 0 10V

Off/“0”

Off/“0”

Output 1 10V

Off/“0”

Off/“0”

20mA On/“1”

On/“1”

20mA On/“1”

On/“1”

LA4

Input 2

10V

Off/“0”

On/“1”

Output 1 10V

Off/“0”

Off/“0”

20mA On/“1”

Off/“0”

20mA On/“1”

On/“1”

LA5

Output 0 10V

Off/“0”

Off/“0”

20mA On/“1”

On/“1”

LA6

Input 0

10V

Off/“0”

On/“1”

20mA On/“1”

Off/“0”

LA7

Input 0

10V

Off/“0”

On/“1”

Input 1

10V

Off/“0”

On/“1”

20mA On/“1”

Off/“0”

20mA On/“1”

Off/“0”

1

2

On / 1 =

Off / 0 =

Switches S1 and S51

Advertising