Blow-molding Module 43

Publication 1746-IN014B-EN-P - January 2001

Descriptions of module parameters

Module Parameter

Description

axis control structure

64 axis-configuration words that you enter in the M0 file

axis current adc input

raw 14-bit value read from adc (for LVDT position counts)

axis current control output

16-bit integer

axis current dac output

raw 14-bit value written to dac

axis current process variable

16-bit integer representing the position input

axis current profile step

indicates which step of a profile is currently executing

axis current setpoint

indicates axis target position (can be unrelated to the profile)

axis full-scale point

calibrated maximum travel limit of LVDT

axis zero-scale point

calibrated minimum travel limit of LVDT

axis process-variable profile

256 words in M1 file to indicate actual setpoint execution

axis setpoint profile

256 words in M0 file to control parison head or accumulator

axis synchronization input

command trigger to start drop of the parison

axis synchronization output

signal used to synchronize external hardware with a profile step

interpolated setpoint profile

returned master profile filled with module-computed setpoints.

master setpoint profile

selected critical profile setpoints in M0 file. Other setpoints = 0

operation: position-based mode

profile steps triggered by position inputs from LVDT

operation: time-based mode

profile steps triggered by module-computed time intervals

parison weight adjustment

capability to offset entire profile to adjust weight of parison-

profile scale adjustment

capability to change profile scale without changing part weight

setpoint marking

capability to relate a setpoint in the profile to a ridge in the part

shotsize

length of screw backup to inject a full shot of melt

signed-integer format

minimum value of -32768 corresponds to zero-scale (fully-closed or
fully-forward) and the maximum value of +32767 corresponds to full-scale
(fully-open or fully-retracted).