Direct Communication Module 5

Publication 1747-IN005B-EN-P - March 2003

System Overview

The Direct Communication Module, catalog number 1747-DCM, connects any

SLC 500

programmable controller with expansion chassis or SLC 500 Modular

Programmable Controller to a supervisory Allen-Bradley programmable controller
via the RIO Link, providing a distributed processing system. The 1747-DCM allows
these supervisory processors to transfer data between one another. The 1747-DCM
appears as an RIO adapter to:

a PLC

processor with integral RIO scanner on the RIO Communication Link

an RIO scanner, catalog number 1771-SN or 1747-SN, on the RIO
Communication Link

The 1747-DCM can physically reside on the RIO Link with any other adapter. It is
compatible with all RIO scanners.

1747-DCM Modules are connected in a daisy-chain configuration using
Belden™ 9463 cable. See the example below.

Supervisory PLC or SLC

Distributed SLCs with
DCMs (adapters)

PanelView™ (adapter)

DCM 2

DCM 3

DCM 1

RIO Scanner