Wire the rs-485 ascii module s, Wire the rs-485 ascii modules – Rockwell Automation 1738-485ASCM12 ArmorPoint I/O RS-485 ASCII Module, Series A User Manual

Page 7

Advertising
background image

Publication 1738-IN010A-EN-E - June 2004

ArmorPoint I/O RS-485 ASCII Module, Series A 7

Wire the RS-485

ASCII Modules

Following are wiring instructions for the ArmorPoint RS-485 ASCII
module.

1738-485ASCM12

IMPORTANT

The 1738-485ASCM12 module has earth grounded
metal rings. This should be considered when
choosing shielded cables and grounding techniques.

ATTENTION

Make sure all connectors and caps are securely
tightened to properly seal the connections against
leaks and maintain IP67 requirements.

(view into connector)

Pin 1 -

Tx -

Pin 2 -

Tx +

Pin 3 -

Rx +

Pin 4 -

Rx -

Pin 5 -

No Connect