AC (24V) Input Module 5

The 1771-IN module is a modular component of the 1771 I/O system
requiring a properly installed system chassis. Refer to publication 1771-IN075
for detailed information on acceptable chassis, proper installation, and
grounding requirements. Limit the maximum adjacent slot power dissipation
to 10W maximum.

Connect Wiring to the Field
Wiring Arm

Make wiring connections to the module through the 10 terminal field wiring
arm (cat. no. 1771-WA). The arm pivots on the I/O chassis to connect with
terminals on the front of the module and acts as a terminal strip. The wiring
arm allows the module to be removed from the chassis without disconnecting
the wiring.

Place the module in the card guides on the top and bottom of the
chassis that guide the module into position.

Important:

Apply firm even pressure on the module to seat it

into its backplane connector .

1

1771-A1B, -A2B, -A3B, -A4B I/O chassis

Snap the chassis latch over

the top of the module to

secure it.

Swing the chassis locking bar
down into place to secure the
modules. Make sure the
locking pins engage.

1771-A1B, -A2B, -A4B Series B I/O chassis

2

1771-WA

The wiring arm pivots upward and connects with the
module so you can install or remove the module
without disconnecting the wires.

Attach the wiring arm (1771-WA) to the horizontal bar
at the bottom of the I/O chassis.