Table of burner and nozzle specifications – Hotpoint Ariston CX 65 SP4 R/HA User Manual

Page 18

Advertising
background image

18

GB

Table of burner and nozzle specifications

Table 1

Liquid Gas

Natural Gas

Burner

Diameter

(mm)

Thermal Power

kW (p.c.s.*)

By-Pass

1/100

Nozzle

1/100

Flow*

g/h

Nozzle

1/100

Flow*

l/h

Nozzle

1/100

Flow*

l/h

Nominal

Reduced

(mm)

(mm)

***

**

(mm)

(mm)

Fast
(Large)(R)

100

3,00

0,7

41

86

218

214

116

286

143

286

Semi Fast
(Medium)(S)

75

1,90

0,4

30

70

138

136

106

181

118

181

Auxiliary

(Small)(A)

55

1,00

0,4

30

50

73

71

79

95

80

95

Triple Ring

(TC)

130

3.25

1.5

63

91

236

232

133

309

150

309

Supply
Pressures

Nominal (mbar)

Minimum (mbar)

Maximum (mbar)

28-30

20
35

37
25
45

20
17
25

13

6,5

18

*

At 15°C and 1013 mbar - dry gas

**

Propane P.C.S. = 50.37 MJ/kg

***

Butane P.C.S. = 49.47 MJ/kg

Natural P.C.S. = 37.78 MJ/m³

TC

A

S

R

CX65SP4 R /HA

TECHNICAL DATA

Oven dimensions

(HxWxD)

32x43.5x40 cm

Volume

56 l

Useful

measurements

relating to the oven

compartment

width 42 cm

depth 44 cm

height 8.5 cm

Burners

may be adapted for use with any

type of gas shown on the data plate

Voltage and

frequency

see data plate

ENERGY LABEL

Directive 2002/40/EC on the label

of electric ovens.

Regulation EN 50304

Energy consumption for Natural

convection – heating mode:

:

Traditional mode

;

Declared energy consumption for

Forced convection Class –
heating mode:

K

Baking.

EC Directives: 73/23/EEC dated

19/02/73 (Low Voltage) and

subsequent amendments -

89/336/EEC dated 03/05/89

(Electromagnetic Compatibility)

and subsequent amendments -

90/369/EEC dated 29/06/90 (Gas)

and subsequent amendments -

93/68/EEC dated 22/07/93 and

subsequent amendments -

2002/96/EC.

Advertising