After Each Use

Water should not remain in the pump chamber for long
periods of time. Sediments and minerals can deposit on
pump parts and cause poor pump performance. Follow these
procedures after every use:

Flush and Drain Trash Pump and Clean the Impeller

1. Stop engine following instructions in Stopping the

Trash Pump.

2. Disconnect the spark plug wire from the spark plug and

place the wire where it cannot contact spark plug.

3. Disconnect and drain suction and discharge hoses.

4. Remove priming plug from top of pump and fill with

clean water.

5. Remove both drain plugs at bottom of pump.

6. Replace all plugs and finger tighten.

7. Loosen the two large triangular knobs (A), inserting a

tool in the grooves on the knobs to assist with leverage.

8. Swing the faceplate clamps (B) to the side.

9. Remove the faceplate from the pump chamber.

10. Clean out any debris inside the impeller (C) and the

volute (D). The volute is bolted to the inside of the
pump faceplate, and should not need to be removed.
A garden hose can be used to flush out either area.

11. To ensure a good seal, clean the sealing surfaces (E) in

the pump chamber and the o-rings on the faceplate (F)
before reinstalling the faceplate.

12. Reinstall the faceplate with the drain plug at the

bottom.

13. Bring the faceplate clamps back to the front, fitting

them securely onto the faceplate.

14. Screw down the two large triangular knobs, inserting a

tool in the grooves on the knobs to tighten firmly.

14

BRIGGSandSTRATTON.COM

WARNING

Unintentional sparking can result in fire or
electric shock.

• NEVER pull recoil starter handle with spark plug removed.

B

A

D

C

E

F