Troubleshooting

Problem

Cause

Correction

No pump output or low pump
output when trash pump is
running.

1. Pump not primed.

2. Suction hose restricted, collapsed,

damaged, too long, or diameter too
small.

3. Strainer not completely under water.

4. Air leak at suction hose connector.

5. Strainer clogged.
6. Impeller clogged.
7. Discharge hose restricted, damaged, too

long, or diameter too small.

8. Excessive or marginal head.

9. Engine speed lever is in “Slow” (

)

position.

1. Fill pump chamber with water and

prime pump.

2. Replace suction hose.

3. Sink the strainer and the end of

suction hose completely under water.

4. Replace sealing washer if missing or

damaged. Tighten hose connector
and clamp.

5. Clean debris from strainer.
6. Clean impeller. See After Each Use.
7. Replace discharge hose.

8. Relocate pump and/or hoses to

reduce head.

9. Move engine speed lever to

Fast” (

) position.

Engine will not start; lacks
power; starts and runs rough;
or "hunts" or falters.

1. Rocker switch set to "Off".
2. Fuel valve is in "Off" position.
3. Dirty air cleaner.
4. Out of fuel.
5. Stale or contaminated fuel or water in

fuel.

6. Spark plug wire not connected to spark

plug.

7. Bad spark plug.
8. Excessive fuel is present in the air/fuel

mixture causing a “flooded” condition.

9. Carburetor is out of adjustment.

1. Set switch to "On".
2. Turn fuel valve to "On" position.
3. Clean or replace air cleaner.
4. Wait two minutes and fill fuel tank.
5. Drain fuel tank and carburetor; fill

with fresh fuel.

6. Connect wire to spark plug.

7. Replace spark plug.
8. Wait 5 minutes and re-crank engine.

9. Contact Authorized service facility.

Engine shuts down when
running.

Out of fuel.

Wait two minutes and fill fuel tank.