Rockwell Automation 1440-VDRP06-00RH XM-162 Direct Vibration Modules User Manual

Page 10

Advertising
background image

10

Rockwell Automation Publication GMSI10-IN026C-EN-P - February 2014

XM-160, XM-161, and XM-162 Direct Vibration Modules

Emissions
CISPR 11 (IEC 61000-6-4)

Class A

ESD immunity
IEC 61000-4-2

8 kV air discharges

Radiated RF immunity
IEC 61000-4-3

10V/m with 1 kHz sine-wave 80% AM from 80…2000 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 900 MHz
10V/m with 200 Hz 50% Pulse 100% AM at 1890 MHz
3V/m with 1 kHz sine-wave 80% AM from 2000…2700 MHz

EFT/B immunity
IEC 61000-4-4

±2 kV at 5 kHz on shielded power ports
±2 kV at 5 kHz on shielded signal ports
±2 kV at 5 kHz on XMbus port

Surge transient immunity
IEC 61000-4-5

±2 kV line-earth(CM) on shielded power ports
±2kV line-earth(CM) on shielded signal ports
±2kV line-earth(CM) on XMbus port

Conducted RF immunity
IEC 61000-4-6

10V rms with 1 kHz sine-wave 80% AM from 150 kHz…80 MHz

Enclosure type rating

None (open-style)

Voltagesranges

XM-160/XM-162 Supply:
24V DC, 0.19 A

XM-161 Supply:
24V DC, 0.31 A

Power dissipation

XM160/XM-162: 4.6 W @ 24V DC (4.3 W @ 18V DC, 4.9 W @ 32V DC), Class 2/SELV
XM-161: 7.4 W @ 24V DC (7 W @ 18V DC, 8 W @ 32V DC), Class 2/SELV

External over-current protection

440-5AFUSEKIT for SELV/PELV power source

Isolation voltage

Not rated

Wiring category

(1)

2 - on shielded power and shielded signal ports
3 - on Serial ports
2 - on XMbus ports

Wire type

Power and signal connections: shielded

North American temp code

T4

IEC temp code

T4

(1) Use this Conductor Category information for planning conductor routing. Refer to Industrial Automation Wiring and Grounding Guidelines, publication

1770-4.1

.

Attribute XM-16X

Advertising