Each module has eight status indicators, which are on top of the module.

Module Status (MS) Indicator

Network Status (NS) Indicator

Color

State

Description

No color

Off

No power applied to the module.

Green

Flashing Red

Module performing power-up self-test.

Flashing

Module operating in Program mode.

(1)

(1) Program mode - Typically this occurs when the module configuration settings are being updated with the Serial Configuration Utility. In Program mode, the module does not perform its normal functions.

The signal processing/measurement process is stopped, and the status of the alarms is set to the disarm state to prevent a false alert or danger status.

Solid

Module operating in Run mode.

(2)

(2) Run mode - In Run mode, the module collects measurement data and monitors each measurement device.

Red

Flashing

Application firmware is invalid or not loaded. Download firmware to the module.
Firmware download is currently in progress.
The module power voltage is incorrect

Solid

An unrecoverable fault has occurred. It is possible that the module must be repaired or replaced.

Color

State

Description

No color

Off

Module is not online:
Module is autobauding.
No power applied to the module; look at Module Status indicator.

Green

Flashing

Module is online (DeviceNet network) but no connections are currently established.

(1)

(1) Normal condition when the module is not a slave to an XM-16x module, programmable controller, or other master device.

Solid

Module is online with connections currently established.

Red

Flashing

One or more I/O connections are in the timed-out-state.

Solid

Failed communication (duplicate MAC ID or bus-off).