29707 012502

11. Disconnect the two white wires from the tank

warmer blanket.

12. Disconnect the black, white and blue wires from

the tank heater terminals. DV models only, dis-
connect the brown and red wires from tank heater
terminals.

13. Remove the four #8-32 nuts securing the tank to

the mounting brackets and remove the tank as-
sembly.

14. Remove the eight #8-32 nuts securing the tank lid

to the tank.

15. Remove the two hex nuts securing the tank heater

to the bottom of the tank. Remove tank heater with
gaskets and discard.

16. Install new tank heater with gaskets to the bottom

of the tank and secure with two hex nuts.

17. Install tank assembly onto mounting brackets and

secure in place with four #8-32 nuts.

18. Install tank lid and secure in place with eight #8-32

nuts.

19. Connect the two white wires of the tank warmer

blanket.

SERVICE (cont.)

TANK HEATERS (cont.)

P1888

TANK HEATER TERMINAL BLOCK WIRING DIAGRAM

(CDBC-MV MODELS)

RED

WHI

BLK

RED

WHI

BLK

BLK

WHI

RED

120V A.C.

120V A.C.

208 or

240V A.C.

WHITE

NEUTRAL

L1 BLACK

L2 RED

L2 RED

L2 RED

1800W @ 120V

1425W @ 120V

2390W @ 120/208V

or

3180W @ 120/240V

120V A.C.

WHITE

NEUTRAL

L1 BLACK

120V A.C.

WHITE

NEUTRAL

L1 BLACK

1800W

1425W

B
L
K

B
L
U

W

H

T

1800W

1425W

B
L
K

B
L
U

W

H

T

1800W

1425W

B
L
K

B
L
U

W

H

T

FIG. 9 TANK HEATER TO TERMINAL BLOCK WIRING

20. Connect the limit thermostat to the front of the tank

assembly.

21. Connect the green wire to the tank mounting

bracket using #8-32 nut.

22. Connect the pink wire to the level probe.
23. Insert the temperature probe through the grom-

met in the tank lid.

24. Install the elbow fitting of the vent hose into the

grommet in the tank lid.

25. On brewers with faucet, connect the outlet water

line of the faucet to the side of the tank and secure
with clamp.

26. Connect the water supply tube from the solenoid

to the bottom of the tank and secure with clamp.

27. Connect the water supply tube from the dispense

valve to the side of the tank and secure with clamp.

28. DV models only - Refer to the

Wiring Diagrams

when reconnecting the tank heater wires.
MV models only - Refer to FIG. 9 when reconnect-
ing the tank heater wires.

29. Install access panels and covers and refer to

Initial

Set-up

for refill and operation.