User notices, Caution – Bunn CDBC-APS DV User Manual

Page 3

Advertising
background image

Page 3

#00658.0000

#00831.0000

#29710.0000 (MV models only)

THREE WARMER BREWERS

Optional Field Wiring

120 V, 17.0 A, 2050 W

1PH, 2-Wire, 60HZ

or

120/208-240 V, 13.6-15.3 A, 2640-3430 W

1PH, 3-Wire, 60HZ

#29710.0002 (MV models only)

TWO WARMER BREWERS

Optional Field Wiring

120 V, 18.0 A, 2150 W

1PH, 2-Wire, 60HZ

or

120/208-240 V, 14.4-16.2 A, 2740-3530 W

1PH, 3-Wire, 60HZ

29707 080503

Optional Field Wiring

120/208-240 V, 14.4-16.2 A, 2740-3530 W

1PH, 3-Wire, 60HZ

#29710.0003 (DV models only)

THREE WARMER BREWERS

Optional Field Wiring

120/208-240 V, 12-13.7 A, 2440-3230 W

1PH, 3-Wire, 60HZ

#29710.0004 (DV models only)

APS BREWERS

When re-wiring the machine for operation on

120/208V or 120/240V, the replacement Power

Supply Cord must be UL Listed Flexible Cord Type

SO, SJO, SJTO, HSJO or SJOW, No. 12 AWG, 4

Conductor, Rated 90

°

C. Attachment Plug Cap

must be UL Listed, NEMA 14-20P or L14-20P

Configuration, Rated 125/250V, 20 AMPS. The

Power Supply Cord must be at least 3 feet long

and maximum 6 feet long (measured from Strain

Relief to end of the Attachment Plug Cap.)

!

CAUTION

#34072.0000

USER NOTICES

Carefully read and follow all notices in this manual and on the equipment. All labels on the equipment should
be kept in good condition. Replace any unreadable or damaged labels.