Antelope Audio DA Distribution Amplifier User Manual

Page 5

Advertising
background image

Rear Panel

10ft. (3m.).

Power Connection

This IES AC connection accepts an input of 95-245 VAC 50/60 Hz. As a result, the OCX
automatically accommodates a full range of voltages, allowing safe use in any country.

S/PDIF input and S/PDIF thru

The S/PDIF in is an RCA connection that accepts clock via Coaxial S/PDIF The S/PDIF thru
will reamplify and output any audio contained in signal received by the S/PDIF input.

AES/EBU input and AES/EBU thru

The AES/EBU in is an XLR connection that accepts clock via AES/EBU The AES/EBU thru
will reamplify and output any audio contained in signal received by the AES/EBU input.

Word Clock input 1 and 2

BNC connections used to accept clock for distribution.

Word Clock outputs 1-6

The sample rate provided by these outputs always matches the sample rate indicated by
the Frequency Display on the front panel.

Word Clock outputs 7-8 The sample rate provided by these two outputs can either

match the sample rate of outputs 1-6, or can be changed to alternate sample rates by using
their corresponding knobs on the front panel.

AES/EBU outputs

Output clock to devices with AES / EBU inputs.

S/PDIF outputs

Output clock to devices with S/PDIF inputs.

Maximum Cable lengths:
Too long of a cable run can cause unwanted jitter and clock error. For optimum results,
Word Clock cables should be no longer than 20ft. (6m.), AES/EBU no longer than 300ft.
(90m.), and S/PDIF no longer than