4.3. Command Set

4.3.1. Command List for Local Device

Item Syntax

Description

Remarks

1. Connecting

address

A

Addr<Enter> Set a remote device

address for a wireless

connection.

A local and remote

BD_ADDR always need to

be difference.

2. Baud rate

B

Baud Rate

Change the baud rate

Baud Rate - 0: 1200, 1:

2400, 2: 4800, 3: 9600, 4:

19200, 5: 38400, 6: 57600,

7: 115200

3. COM port

C

COM Port

This is only valid in connection

mode 2.

4. PIN code

E

PIN<Enter>

Authentication Off: Type <Enter>

Authentication On: Type up to 11

characters

Paired adapters should

have a same PIN code.

5. Flow control

F

Flow Control

Set the Flow control.

0: None, 1: Hardware, 2:

DTR/DSR, 3: Hardware &

DTR/DSR

6. Connection

mode

M

mode

Set a connection mode

0: 1:1 Mode, 1: WAIT Mode,

2: REGISTER and

CONNECT Mode

7. Friendly name

N

name<Enter> Set a friendly name up to 11

characters.

8. Command for

the remote

O

Enter configuration mode

for the remote.

9. Parity Bit

P

parity

Set the parity bit.

0: None, 1: Odd 2: Even

10. Stop Bit

S

stop

Set the stop bit.

0: 1 Stop, 1: 2 Stop

11. View

V

Display

configuration

information

12. Exit

X

Apply changes.

13. Usage

?

Print the usage.

Waning!

If you push the RST button, the COM port of HPS-120 will be stored the factory setting.