Bally Refrigerated Boxes Wiper Gasket Replacement User Manual

Field replacement: wiper gaskets, Instructions

Advertising
background image

REV: 1/2013

2013 © Bally Refrigerated Boxes, Inc. 1

FIELD REPLACEMENT:

WIPER GASKETS

Instructions:

1. Disconnect the power supply to the vapor-proof light

junction box on the interior of the door panel.


2. Disconnect the crossover cord from the vapor-proof

light junction box. Allow the cord to hang free from

the door cap.


3. Unscrew hinge screws from door panel and carefully

remove door cap.

4. Lay door cap on work surface with the door cap

interior facing up.

5. Drill out 1/8" rivets that mount dual gasket assembly

using a 9/64" drill. Remove dual gasket assembly.

6. Install new 1/8" rivets into existing holes.

7. Inspect and clear plastic extrusion ridge that runs

along the inside of door offset.

8. After centering new gasket along bottom of door cap,

drive gasket stem into ridge using wood block and,
hammer with light taps.


9. Reinstall door and connect power.


10. New gasket should slightly drag on step plate or floor

surface. Gasket may need to be trimmed if it drags

excessively and inhibits door closure.


For doors manufactured before 1980 see other side.