Instructions for pre 1980’s doors, Alternate installation – Bally Refrigerated Boxes Wiper Gasket Replacement User Manual

Page 2

Advertising
background image

REV: 1/2013

2013 © Bally Refrigerated Boxes, Inc. 2

Instructions for Pre 1980’s Doors:


1. Disconnect the power supply to the vapor-proof light

junction box on the interior of the door panel.

2. Disconnect the crossover cord from the vapor-proof

light junction box. Allow the cord to hang free from
the door cap.

3. Unscrew hinge screws from door panel and carefully

remove door cap.

4. Lay door cap on work surface with the door cap

interior facing up.


5. Loosen mounting bolts for gasket retainer plate and

remove old gasket. Move retainer plate forward to

cover cavity and tighten bolts.


6. Inspect and clear plastic extrusion ridge that runs

along the inside of door offset.

7. After centering new gasket along bottom of door cap,

drive gasket stem into ridge using wood block and,
hammer with light taps.


8. Reinstall door and connect power.

9. New gasket should slightly drag on step plate or floor

surface. Gasket may need to be trimmed if it drags

excessively and inhibits door closure.


Alternate Installation:


10. If door cap does not have plastic extrusion along

bottom, install new gasket stem under retainer plate.
Ensure that gasket firmly sets against the inside of

door cap offset.