Bunn FCD-4 User Manual

Page 19

Advertising
background image

19

Dispense Fault List

“REFILL” indicator

Beeper

Fault

2 flashes

2 beeps

Dispense station locked out.

3 flashes

3 beeps

DISPENSE/RINSE sensing fault.

4 flashes

4 beeps

DISPENSE/RINSE knob mis-positioned.

5 flashes

5 beeps

Pump motor stalled/speed sensor inoperative.

All “REFILL”

3 beeps

Dispenser locked out.

indicators flash

3 times

Dip Switch Function List

Dip Switch Controls

Off

On

1

“REFILL” indicator when “concentrate out” is detected.

Inactive

Active

2

Lockout dispense components when “concentrate out” is detected.

Inactive

Active (Note)

3

Number of positions that can dispense/rinse simultaneously.

3

2

4

Rinse timer

Off

On

5

Audio feedback during dispenses.

On

Off

6

Future use.

None

None

Note: When dip switch 2 is in the “on” position, the “REFILL” indicator is active, regardless of dip switch 1

position.

Cooling Fault List

Fault Code

“COOLING”

DBC display

Fault

Fault

indicator

(optional)

Priority

8

8 flashes every

fault 8

Bath water level low.

1

5 seconds

(Also lights all “WATER” indicators)

7

7 flashes every

fault 7

Bath temperature probe short circuit.

2

5 seconds

6

6 flashes every

fault 6

Bath temperature probe open circuit.

3

5 seconds

5

5 flashes every

fault 5

Cabinet temperature probe short circuit.

4

5 seconds

4

4 flashes every

fault 4

Cabinet temperature probe open circuit.

5

5 seconds

3

3 flashes every

fault 3

Cooling system failure

6

5 seconds

(disables all dispense functions)

0

On steady

Bath/cabinet

Bath and cabinet temperatures excessive.

7

temperatures

2

2 flashes every

Bath/cabinet

Bath temperature excessive.

8

5 seconds

temperatures

1

1 flash every

Bath/cabinet

Cabinet temperature excessive.

9

5 seconds

temperatures

33496 030901