Troubleshooting, Problem probable cause what to do – Baumfolder Wetscore User Manual

Page 12

Advertising
background image

TP10320A

PAGE 12

TROUBLESHOOTING

PROBLEM

PROBABLE CAUSE

WHAT TO DO

Poor or no flow from needles

Sensor LED is lit when holding
your hand under it:

1. No water in the bottle

Fill bottle with solution

2. Excessive air in the tubing

Bleed air from tubing

3. Tip of the needle is excessively

Replace

worn

4. Control valve is closed

Open

5. Needle is not in contact with

Adjust

the sheet

6. Solids trapped in needles

Remove the needles from the nozzles
and blow out the needles with an air
compressor

Sensor LED not lit when holding
your hand under it:

1. WetScore unplugged

Plug in outlet

2. Malfunction in Modulated Amp.

Contact your dealer Rep.

Solution leaks at needle/nozzle
connection

1. Needle is cracked

Replace

2. Needle is not securely

Tighten

fastened to nozzle

Sheet is excessively wet,
score not a fine line

1. Flow rate is to great

Adjust control valve for
proper flow

2. Needle is to large for light

Change to smaller guage needle
weight sheet

3. To much water in solution

Remix solution using

greater amount of alcohol

4. Coating of sheet is to great

Recommend use of mechanical scoring

for WetScore use