Troubleshooting, Problem probable cause what to do – Baumfolder Wetscore User Manual

Page 13

Advertising
background image

PAGE 13

TP10320A

TROUBLESHOOTING

PROBLEM

PROBABLE CAUSE

WHAT TO DO

Build up of fluid upon

register table

1. Improper setting of nozzle

Readjust nozzle between register

within nozzle holder

tape drive roller and register table

Inconsistent Folds

1. Positioning of WetScore

Readjust to proper position

needles is out of register

2. Poor or no flow from

See above

needles

3. Folder plate stop set off of

Readjust to proper position

proper position

4. Alignment ofWetScore needle to

Realign the WetScore needle to the

mechanical score is improper

mechanical score

Ink is offseting along the
folded edge

1. Sheet coating is to dense for

Use of WetScore is not recommended

absorbtion of alcohol solution,
alcohol is breaking down the ink

Solution leaks from control
valve port

1. PVC tubing hardened

Replace, see instructions

and brittle

2. Control valve has

Replace

cracked

Needles do not shut off

1. Sensor is set to low

Adjust sensor so that the LED light is
off when sheet is absent

Discoloration of signatures
along
scored edge

1. Paper stock is highly alkaline

Reduce the amount of alcohol in

(acid free paper)

solution to approx. 30%