Baumfolder Flexifold: 1st Station (in 2004) User Manual

Page 31

Advertising
background image

PAGE 31

TP10494

1. Using the numerical buttons ( ) enter the

desired batch size; one, two or three digits (maximum

setting is 999).

2. Using the “+” and ”-“ buttons, enter the desired

feed interrupt time (0.3 to 9.9 seconds). This gives the
separation.

When stop is displayed, pressing the “SHEET START

button will feed a batch and stop. Press the “SHEET
START
” button to process the next batch.

11.3 Resetting the batch count.

To reset the batch counters press the “RESET” but-

ton, then press the “SET BATCH” button. This will reset

the batch count and the total batches. The Total Count will

not be reset.

11.4 Rate

The “RATE” button is used to display the average

pieces per hour, both current and average since the last total

counter reset.

Pressing the “RATE” button will change the display

to the rate screen consisting of two lines. The top line is the

current rate. It will have a 5 digit display, and will refresh

every 6 seconds. The second line will show the average

pieces per hour since the last total counter reset. This line

will also have a 5 digit display, and refresh every 30 sec-

onds.

The display will stay in this mode until another mode

button is pressed. The “ENTER” and “RESET” buttons

will have no affect in this mode.

NOTE: Every time the total count is reset the

average rate per hour will also be reset.

NOTE: If a button is not pressed within 2 minutes the

machine will return to the operating mode.

SET BATCH

### #.#

TOTAL COUNT #######

BATCH ### #####

CURRENT RATE #####

AVERAGE RATE #####

Advertising