Troubleshooting – Bendix Commercial Vehicle Systems MC-11 TRACTOR ANTILOCK 4/04 User Manual

Page 16

Advertising
background image

16

RECORD INDICATED
FAILURE. PERFORM
A RESET.

DISCONNECT THE 4-PIN

CONNECTOR BETWEEN THE

EC-11

CONTROLLER AND THE

M-12

MODULATOR SOLENOID

ASSEMBLY. CHECK RESISTANCE
ACROSS BOTH PAIRS OF WIRES.

(WHITE-WHITE, BLACK-BLACK)

CHECK FOR
SHORT-BLACK TO
CASE GROUND
AND WHITE TO
CASE GROUND

INTERMITTENT CONNECTION
BETWEEN EC-11

CONTROLLER

AND M-12

MODULATOR.

CHECK 4-PIN CONNECTOR

REPLACE M-12

MODULATOR

“MOD” LED
STAYS ON

REPEAT STARTUP

“MOD” LED
GOES OFF

STILL ON?

WHITE

BLACK

RESISTANCE
WITHIN 9.5-
11.5 OHMS

REPEAT STARTUP

REPLACE EC-11

CONTROLLER

NO CONTINUITY

CONTINUITY

REPLACE M-12

MODULATOR

RESISTANCE
OUTSIDE 9.5-
11.5 OHMS

TROUBLESHOOTING

SECTION V - TESTING MODULATOR

MAGNET HERE
TO RESET